On Sun Systems, a Small Number of 256MB DIMMs May Experience Premature Failures with Uncorrectable Memory Error (UE) Messages



Category :Availability
Release Phase :Resolved
Product :Sun Fire 12K Server
Sun Blade 2000 Workstation
Sun Fire 280R Server
Sun Fire V880 Server
Netra 20 Server
Sun Fire 3800 Server
Sun Fire 4800 Server
Sun Fire 4810 Server
Sun Fire 6800 Server
Sun Fire 15K Server
Sun Blade 1000 Workstation
Sun Fire V480 Server  
Bug Id :None  
Date of Workaround Release :14-FEB-2003 
Date of Resolved Release :23-MAR-2004 


Impact

Sun has identified a set of 256MB DIMMs that may experience premature failures displayed as uncorrectable memory error (UE) messages. A 12 week date code range of B-die 256MB DIMMs in total are affected.

The described issue typically occurs during the first 50 weeks of memory module usage.


Contributing Factors

This issue can occur in the following releases:

SPARC

  • 256MB DIMM with Part Number 501-5401-02 or 501-5401-03

And with a module date code between 0115 and 0127 which are B-die modules built between weeks 15 and 27 of 2001. (Note the module date code is given on a white label on the DIMM)

In order to identify affected DIMMs in a system, the approximate overall serial number range is:

	501540178190000 to 501540178310000

A physical check can be performed on the part number (also given on a white label on the DIMM) to verify it is a B-die. The following part number is an example of a B-die DIMM:

	M323S1742BT2-C1LS0
                 ^
                 |  Denotes B-die

C-die DIMMs would have a "C" in place of the "B" as seen above.

Note: The format for serial numbers (for example, 501540178190000) is :

5015401 Sun Part Number
78 Vendor Code
nnnnnn Unique Identifier (e.g. "190000")

SPARC Platforms that may be affected:

  • Sun Fire (280R, V480, V880)
  • Sun Blade 1000/2000
  • Netra 20
  • Sun Fire Servers (3800/4800/4810/6800)
  • Sun Fire 12K Servers
  • Sun Fire 15K Servers

Symptoms

Sample error messages include:

	Multiple uncorrectable memory failures in a single machine.

and sample specific strings including:

	Multiple Softerrors
	Sticky Softerrors accumulated ... unix:  [ID 340762 kern.notice] from Memory Module ...
	Uncorrectable system bus (UE) Event on CPU0 Privileged Data Access at ...
	WARNING:  [AFT1] EDU Event on CPU0 ...
	ECC errors ..	
	WARNING:  [AFT1]  WDU Event on ...
	UE   EDU   WDU   Error(s)...

Workaround

Please see Resolution below.


Resolution

Upon failure, the affected modules will be replaced. This issue is addressed via a Field Change Order (FCO).




Modification History


Date: 03-NOV-2003
  • Updated Contributing Factors

Date: 23-MAR-2004
  • State: Resolved
  • Updated Resolution section




Attachments
This solution has no attachment

 
 
Login Required

You must login and have a valid contract to access Sun's Premium content which includes:

  • Sun Alerts
  • Bugs
  • Patches
  • Solutions
  • White Papers
  • Documentation
  • Support Knowledge

Login Required

You must login and have a valid contract to access Sun's contracted features

Access Legend:

(Login to access)   Sun Contracted Content
(Login to access)   Sun Contracted Feature

Please make use of SunSolve Feedback application by selecting the floating [+] to provide feedback about this specific document.

Search

Article Details
Article ID : 200742
Article Type : Sun Alert
Last reviewed : 2004-03-23
Audience : PUBLIC
Keywords :
Provide feedback  (help)
Page Tools
»  Print This Page
»  Email This Article
»  Bookmark This Article
 
Contact About Sun News & Events Employment Site Map Privacy Terms of Use Trademarks Copyright Sun Microsystems, Inc. | SunSolve Version 7.4.0 #1