Domains on Sun Fire 3800/4800/4810/4900/6800/6900 Systems May Experience a Domain Pause |
|
| Category : | Availability |
| Release Phase : | Resolved |
| Product : | Sun StorageTek 6900 Series Sun Fire 3800 Server Sun Fire 4800 Server Sun Fire 4810 Server Sun Fire 6800 Server Sun Fire E6900 Server Sun Fire E4900 Server
|
| Bug Id : | 4975114, 5078409, 5081112
|
| Date of Workaround Release : | 30-JAN-2004
|
| Date of Resolved Release : | 02-Apr-2008
|
Domains on Sun Fire 3800/4800/4810/4900/6800/6900 systems ... see below for details:
1. Impact
Domains on Sun Fire 3800/4800/4810/4900/6800/6900 systems with memory configurations of 1-way, 2-way or 4-way interleaving may experience a Domain pause.
2. Contributing Factors
This issue can occur on the following platforms:
SPARC Platform
-
Sun Fire 3800/4800/4810/4900/6800/6900
Platforms configured with two domains in one segment may experience this issue.
3. Symptoms
Should the described issue occur, messages similar to the following may be captured to the system controller logs or output to the domain console:
/partition1/domain0/SB1/ar0:
L2CheckError[0x6150] : 0x00008060
FE [15:15] : 0x1
INCSyncErr [08:05] : 0x3 Ports [9:6] incoming
mismatched against internal expected incoming
DATE TIME Sys_Name Domain-C.SC: [ID 935892 local0.error] [AD]
Event: SF6800
CSN: 223H3028 DomainID: C ADInfo: 1.SCAPP.15.3
Time: Wed Jan 07 12:52:39 PST 2004
FRU-List-Count: 0; FRU-PN: ; FRU-SN: ; FRU-LOC: UNRESOLVED
Recommended-Action: Service action required
Error messages can be retrieved by running the "showlogs -d <domain>" command. The example below searches domain C's message log for "L2CheckError" entries:
SC-Name:SC> showlogs -d c
Dec 29 10:23:51 fada1h6802p Domain-C.SC: [ID 272780 local5.error] ArAsic
reported first error on /N0/SB1
Dec 29 10:23:51 fada1h6802p Domain-C.SC: [ID 807371 local5.error]
/partition1/domain0/SB1/ar0:
L2CheckError[0x6150] : 0x00608060
AccIncSyncErr [24:21] : 0x3 accumulated incoming mismatch
FE [15:15] : 0x1
INCSyncErr [08:05] : 0x3 Ports [9:6] incoming mismatched
against internal expected incoming
Dec 29 10:23:51 fada1h6802p Domain-C.SC: [ID 628853 local5.error] ArAsic
reported first error on /N0/IB7
Dec 29 10:23:51 fada1h6802p Domain-C.SC: [ID 829016 local5.error]
/partition1/domain0/IB7/ar0:
L2CheckError[0x6150] : 0x06068606
CMDVSyncErr [12:09] : 0x3 Ports [9:6] command valid
mismatched against internal expected command valid
PreqSyncErr [04:01] : 0x3 Ports [9:6] prereq mismatched
against internal expected prereq
AccCMDVSyncErr [28:25] : 0x3 accumulated valid command mismatch
FE [15:15] : 0x1
AccPreqSyncErr [20:17] : 0x3 accumulated prerequisite mismatch
Dec 29 10:23:51 fada1h6802p Domain-C.SC: [ID 436815 local5.error] [AD]
Event: SF6800
CSN: 313H3174 DomainID: C ADInfo: 1.SCAPP.15.3
Time: Mon Dec 29 10:23:51 CST 2003
FRU-List-Count: 0; FRU-PN: ; FRU-SN: ; FRU-LOC: UNRESOLVED
Recommended-Action: Service action required
4. Workaround
To work around the described issue, upgrade to 5.17.3 or 5.18.0 AND avoid memory configurations resulting in 1-way, 2-way or 4-way interleaving.
5. Resolution
There are no further updates planned for this Sun Alert document. If
you need additional assistance regarding this issue, please contact Sun
Services.
This Sun Alert notification is being provided to you on an "AS IS"
basis. This Sun Alert notification may contain information provided by
third parties. The issues described in this Sun Alert notification may
or may not impact your system(s). Sun makes no representations,
warranties, or guarantees as to the information contained herein. ANY
AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR
NON-INFRINGEMENT, ARE HEREBY DISCLAIMED. BY ACCESSING THIS DOCUMENT YOU
ACKNOWLEDGE THAT SUN SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT,
INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES THAT ARISE OUT
OF YOUR USE OR FAILURE TO USE THE INFORMATION CONTAINED HEREIN. This
Sun Alert notification contains Sun proprietary and confidential
information. It is being provided to you pursuant to the provisions of
your agreement to purchase services from Sun, or, if you do not have
such an agreement, the Sun.com Terms of Use. This Sun Alert
notification may only be used for the purposes contemplated by these
agreements.
Copyright 2000-2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, CA 95054 U.S.A. All rights reserved.Modification History02-Apr-2008: no further updates. Resolved
Date: 16-DEC-2004
-
Update information and add 3800/4800/4810/4900/6800/6900 systems to Synopsis and Contributing Factors
Date: 17-AUG-2004
-
Changed focus of content to outline "4 way interleave" process
AttachmentsThis solution has no attachment