Sun Blade[tm] 6048 Modular System - Hardware Specifications

Sun Blade[tm] 6048 Modular System: Hardware Specifications

Note: These specifications are for the Sun Blade 6048 chassis.
Memory, CPU, storage, and I/O are Server Module (Blade) specific.
Reference the Servers/Blade section of the Sun System Handbook's Systems List to find Server Modules.

Capacity
Number
  • Up to 24 optional, hot-pluggable PCI ExpressModules (EM) per shelf, 96 per chassis.
  • Up to 2 optional, hot-pluggable PCI Express Network Express Modules (NEM) per shelf, 8 per chassis.
  • Up to 12 optional, hot-pluggable Sun Blade Server Modules per shelf, 48 per chassis.
  • 2 high-efficiency, hot-swappable, 1 + 1 redundant, power supply modules per shelf, 8 per chassis.
  • 2 Front Fan Modules per shelf, 8 per chassis.
  • 8 redundant Rear Fan Modules per shelf, 32 per chassis.
  • 1 Chassis Monitoring Module (CMM) per shelf, 4 per chassis.
Management Environment
Sun Blade 6048 Chassis Monitoring Module (CMM)
  • Sun Blade 6048 chassis-level management is provided by the CMM's Integrated Lights-Out Management (ILOM) software.
  • Connect to CMM ILOM:
    • Connect a terminal or terminal emulation software to the SER MGT (RJ-45) port of the CMM to telnet into CMM ILOM.
    • Connect to the NET MGT 0 (10/100Base T ethernet) port of the CMM for Secure Shell (SSH) client access to CMM ILOM.
Power Supplies
Number Two, hot-swappable, 1 + 1 redundant, load balancing power supplies per shelf, 8 per chassis.
Configurations
  • 8400 Watt power supply. Each power supply has 3 AC inputs. When all three inputs are used, 8400 Watts of power are supplied to the chassis.
Power Calculator Sun Blade 6048 - Power Calculator
Standard Integrated Interfaces
Network The Sun Blade 6048, without an optional EM or NEM, does not offer production network or I/O connectivity.
PCI Interfaces The Sun Blade 6048 Modular System I/O is architected using PCI Express technology. I/O is offered in two form factors: PCI Express ExpressModules (EM) and PCI Express Network Express Modules (NEM). Each server module has four PCI Express links.
There are 2 mid-plane versions: PCI Express 1.1 and PCI Express Gen 2.
Removable Media n/a
Environment
AC input
  • Voltage: 200-240 VAC.
  • Frequency: 50-60 Hz.
  • Current: 16A per AC input.
  • AC Input Connections: Dependent on location:
    • AMER - L6-20P to IEC 320 C19; 2.5m; Sun PN 180-2005-01.
    • EPAC - IEC 309 to IEC 320 C19; 2.5m; Sun PN 180-2004-01.
Temperature Operating: 5°C to 32°C (41° F to 90° F) non-condensing.
Nonoperating: -40°C to 65°C (-40° F to 149° F) non-condensing.
Optimum ambient temperature: <23° C (73.40° F).
Relative Humidity Operating: 10% to 90% RH, non-condensing, 27° C max wet bulb.
Nonoperating: 45% to 50% RH, non-condensing, 38° C max wet bulb.
Optimum ambient relative humidity: 45% to 50% RH, non-condensing.
Altitude 0 to 10,000 feet (3,048m).
Sine Vibration Operating: Z (vertical)-axis: 0.15G X/Y axis: 0.10G 5 to 500 Hz sine.
Nonoperating: Z (vertical)-axis: 0.50G X/Y axis: 0.25G 5 to 500 Hz sine.
Shock 3Gs, 11msec, half sine (applied to rackmounted enclosure).
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Product Safety
  • UL approved to UL 60950 and C22.2 No. 60950.
  • UL Demko approved to EN60950-1 and CB Report IEC 950 3rd Edition; including all amendments and full worldwide deviations.
  • GOST Certification.
  • Korean MIC Certification.
  • China CCC Mark for power supply only (system is exempt since it is rated greater than 1300W).
  • CE Declaration of Conformance to the Electronic Compatibility Directive and Low Voltage Directive 2006/95/EC.
  • IRAM S-Mark for power supply (system is exempt, due to class of equipment)
  • CNS 14336 (Taiwan).
Laser Product and Optical I/O
  • FCC registration to Code of Federal regulations 21 CFR 1040-Lasers.
  • TUV approval to IEC 60825-1 Safety of Laser Products.
  • Canadian Radiation Emitting Devices Act REDR C1370.
Emissions and Immunities:
Electromagnetic Interference
  • 47 CFR 15B (Code of Federal Regulations, Part 15, Subpart B) Class A.
  • EN55022:2006 Class A per EMC directive 2004/108/EEC (CE Mark).
  • VCCI Class A.
  • Industry Canada ICES-003.
  • AS/NZ 3548 (Australia/New Zealand).
  • CNS 13438 (Taiwan).
Immunity
  • EN55024:1998+A1:2001 +A2:2003 per EMC Directive 2004/108/ EEC, including: IEC 61000-4-2 Electrostatic discharge immunity test.
  • IEC 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test.
  • IEC 61000-4-4 Electrical fast transient/burst immunity test.
  • IEC 61000-4-5 Surge immunity test.
  • IEC 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields.
  • IEC 61000-4-8 Power frequency magnetic field immunity test.
  • IEC 61000-4-11 Voltage dips, short interruptions, and voltage variations immunity tests.
Line Distortion EN 61000-3-2 per EMC Directive 89/336/EEC.
Voltage Fluctuations and Flicker EN 61000-3-3 per EMC Directive 89/336/EEC.
Dimensions and Weights
Chassis Height 2,073mm (81.61 in.).
Chassis Width 606.5mm (23.88 in.)
Chassis Depth 1,024.58mm (40.34 in.)
Weight Fully configured system 1,045 kg (2,300 lbs.).
Empty Chassis:
590 kg (1,300 lbs.)

 
 
 
 
 
 