Enterprise 10000 - Full Components List

Sun Enterprise[tm] 10000 Server - Full Components List

Backplanes
Communication
CPU Module
Disks
Ethernet
Fibre Channel
I/O Boards
    Memory
Power
SCSI
System Board
System Service Processor (SSP)
Exploded View
   

Backplanes
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
n/a n/a 501-4348 Centerplane n/a
n/a n/a 501-4346 Centerplane Support Board n/a
n/a n/a 565-1695 Centerplane Power Module Repair Kit n/a
Communication
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X1071A 605-1636 370-3878 HIPPI/P 1.1 n/a
X1080A 605-1649 370-4273 Enterprise System Interface (ESI/P) n/a
X1157A 605-1623 501-3028 SunATM-155/MFiber PCI 4.0 n/a
X1012A 605-1319 501-2603 SunLink ISDN 501-1849
X1070A 605-1631 370-3878 HIPPI/P 1.0 n/a
X1073A 595-4344 370-2868 SBus Cluster Interconnect Card (SCI) n/a
X1142A 605-1610 370-3142 FDDI/S SAS 6.0 n/a
X1143A 605-1609 370-3143 FDDI/S DAS 6.0 n/a
X1144A 605-1616 501-1932 Token Ring Interface/SBus (TRI/S) 4.0 n/a
X1145A 605-1612 501-1725 High Speed Serial Interface/SBus (HSI/S) 3.0 n/a
X1146A 595-5036 501-1931 SBus Serial Parallel Controller (SPC/S) 3.0 n/a
X1147A 605-1620 501-2794 SunATM-155/MFiber 4.0 n/a
X1148A 605-1621 501-2795 SunATM-155/UTP 4.0 n/a
X1149A 605-1622 501-2864 SunATM-622/MFiber 4.0 n/a
X1158A 605-1624 501-3027 SunATM-155/UTP PCI 4.0 n/a
X1159A 605-1625 501-3029 SunATM-622/MFiber PCI 4.0 n/a
X2144A 605-1645 501-1932 Token Ring Interface/SBus (TRI/S) 5.0 n/a
CPU Module
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X2530A 595-4343 501-4178 250MHz UltraSPARC II n/a
X2550A 595-4410 501-4836 250MHz UltraSPARC II 501-4249
X2560A 596-2325 501-4363 333MHz UltraSPARC II n/a
X2570A 595-5065 501-5425 400MHz UltraSPARC II
(4MB Cache Sapphire-Black)
501-4995
501-5585
n/a n/a 501-4995 400MHz UltraSPARC II
(4MB Cache Sapphire-Black)
501-5425
501-5585
X2580A 596-2567 501-5661 400MHz UltraSPARC II 501-5235
501-5762
501-6008
501-6619
501-6622
501-6624
501-5762 400MHz UltraSPARC II 501-5235
501-5661
2580A
(before April 2001)
596-2556 501-5814 400MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored Data SRAM
Mirrored Tag SRAM
501-6619
501-6622
501-6624
501-5815 400MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored Data SRAM
Mirrored Tag SRAM
501-6619
501-6622
501-6624
501-6009 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
Mirrored Data SRAM
Mirrored Tag SRAM
501-6619
501-6622
501-6624
501-5838 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
Mirrored Data SRAM
501-6008
501-6619
501-6621
501-6622
501-6624
501-6008 400MHz UltraSPARC II
(8MB Cache Sapphire-Black)
Mirrored Data SRAM
501-5838
501-6619
501-6622
501-6624
2580A
(after April 2001)
596-2556 501-6619 400MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored Data SRAM
Mirrored Tag SRAM
501-6622
501-6624
501-6624 400MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored Data SRAM
Mirrored Tag SRAM
501-6619
501-6622
2590A 596-3110 501-6620 466MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored SRAM
Mirrored Tag SRAM
501-6623
501-6623 466MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored SRAM
Mirrored Tag SRAM
501-6620
n/a n/a 501-5798 466MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored SRAM
Mirrored Tag SRAM
501-6620
501-6623
501-5816 466MHz UltraSPARC II
(8MB Cache Blaze)
Mirrored SRAM
Mirrored Tag SRAM
501-6620
501-6623
Disks
Option # Top Level
Part #
Description Assembly # Manufacturing
Part #
Substitute
Part #
SG-ARY154A-72R4 596-2984 StorEdge D1000 12-Slot Rackmount
72GB (4 × 18.2GB) 10000 RPM
540-4178

A1000/D1000 FRU
w/ 1" Bracket 540-3024
w/ Plate 340-4288 or 340-6640
or 340-5928 or 340-7269
390-0002 390-0038
390-0060
390-0085
390-0006 n/a
390-0038 390-0002
390-0060
390-0085
390-0043 n/a
390-0048 n/a
390-0066 n/a
390-0085 390-0002
390-0038
390-0060
SG-ARY173A-145R4 596-2985 StorEdge D1000 12-Slot Rackmount
145GB (4 × 36.4GB) 10000 RPM
540-4520

A1000/D1000 FRU
w/ 1" Bracket 540-3024
w/ Plate 340-4288 or 340-6640
or 340-5928 or 340-7269
390-0050 390-0069
390-0051 n/a
390-0052 n/a
390-0065 n/a
390-0069 390-0050
390-0109 n/a
390-0110 n/a
390-0111 n/a
SG-ARY154A-218R4 596-2986 StorEdge D1000 12-Slot Rackmount
218GB (12 × 18.2GB) 10000 RPM
540-4178

A1000/D1000 FRU
w/ 1" Bracket 540-3024
w/ Plate 340-4288
390-0002 390-0038
390-0060
390-0085
390-0006 n/a
390-0038 390-0002
390-0060
390-0085
390-0043 n/a
390-0048 n/a
390-0066 n/a
390-0085 390-0002
390-0038
390-0060
SG-ARY173A-436R4 596-2987 StorEdge D1000 12-Slot Rackmount
436GB (12 × 36.4GB) 10000 RPM
540-4520

A1000/D1000 FRU
w/ 1" Bracket 540-3024
w/ Plate 340-4288
or Plate 340-6640
390-0050 390-0069
390-0051 n/a
390-0052 n/a
390-0065 n/a
390-0069 390-0050
390-0109 n/a
390-0110 n/a
390-0111 n/a
SG-DSK010C-18G 599-2326 StorEdge UniPack - 18.2GB 10000 RPM 540-4305
Disk Drive Assembly
390-0002 n/a
390-0038 n/a
390-0060 n/a
X9645A 595-5120 StorEdge UniPack tray n/a 540-3564 n/a
Ethernet
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X1044A 605-1591 375-0002 Gigabit Ethernet (GBE/P) 1.0 n/a
X1045A 605-1592 375-0003 Gigabit Ethernet (GBE/S) 1.0 n/a
X1049A 605-1597 501-5443 Sun Quad FastEthernet (SQFE/S) 2.0 501-4837
X1059A 605-1535 501-2919 SunFastEthernet Adapter 2.0 (Colossus Lite) n/a
X1140A 605-1602 501-4375 Gigabit Ethernet (GBE/S) 2.0 n/a
X1141A 605-1601 501-4373 Gigabit Ethernet (GBE/P) 2.0 n/a
X1151A 595-5773 501-5524 Sun GigaSwift Ethernet MMF n/a
X2721A 595-4945 370-3795 SuperStack II Entry Hub n/a
X2722A 595-5205 370-3795 SuperStack II Entry Hub n/a
X3151A 595-5773 501-5524 Sun GigaSwift Ethernet MMF n/a
Fibre Channel
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X6727A 595-5853 375-3030 PCI Dual FC Network Adapter+ n/a
X6757A 595-5943 375-3048 SBus Dual FC Network Adapter n/a
SG-XPCI1FC-QF2 * 595-6425 375-3102 2GB PCI Single FC Network Adapter n/a
SG-XPCI2FC-QF2 * 595-6426 375-3108 2GB PCI Dual FC Network Adapter n/a
SG-XPCI1FC-QL2 594-2466 375-3383 2GB PCI-X Single FC Host Adapter, RoHS:Y n/a
X1057A 595-3213 501-2553 Fibre Channel Host Adapter (FC25/S) n/a
X6730A 595-4303 540-2989
501-5266
FC-AL SBus Host Adapter (FC100/S)
501-5202
X6746A 595-5816 540-4372 StorEdge Network FC Switch-8 n/a
X6767A* 595-6425 375-3102 2GB PCI Single FC Network Adapter n/a
X6768A* 595-6426 375-3108 2GB PCI Dual FC Network Adapter n/a
X6799A 595-5830 375-3019 PCI Single FC Host Adapter n/a
* X6767A changed to SG-XPCI1FC-QF2 and X6768A changed to SG-XPCI2FC-QF2 in July 2003
I/O Boards
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
Previous
Part #
2730A 596-2148 501-4478 SBus I/O Board n/a 501-4349
2731A 596-2294 501-4830 PCI I/O Board n/a 500-4779
501-4777
501-4778
PCI I/O Riser Board (3.3V)
PCI I/O Riser Board (5V)
n/a
n/a
n/a
n/a
Memory
Option # Top Level
Part #
Manufacturing
Part #
Option Description Substitute
Part #
X7022A 595-3869 501-2653 (32MB) 256 MB (8 × 32MB DIMMS) n/a
X7023A 595-3870 501-2654 (128MB) 1 GB (8 × 128MB DIMMS) n/a
X7025A 595-4625 501-4776 E10000 Memory Board 501-4351
Power - DC
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X9685A 595-4628 300-1430 Sun Type A135 2000 Watt Power Supply 300-1336
300-1368
Power - AC
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X3875A 595-4624 540-3441 AC Input Module 540-3062
540-4508
n/a AC Input Module Power Requirements
9620A 596-2453 300-1403 2nd AC Power Sequencer 230V
(standard on newer models)
300-1290
n/a AC Power Sequencer Power Requirements
X9681A 595-4627 540-3440 Remote Power Control Module 540-3067
540-3426
SCSI
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
X1018A 605-1568 501-2739 Single-Ended Fast/Wide SCSI/FastEthernet (SunSwift) n/a
X1052A 595-2731 501-1902 Fast Differential SCSI-2/Buffered Ethernet Card (DSBE/S) n/a
X1053A 595-2724 501-2015 Fast SCSI-2/Buffered Ethernet Card (FSBE/S) 501-2981
X1062A 595-3257 370-1704 Differential Fast/Wide SCSI-2 Host Adapter (DWIS/S) n/a
X1063A 595-3258 370-1703 Single-Ended Fast/Wide SCSI-2 Host Adapter (SWIS/S) n/a
X1065A 595-4187 370-2443 Differential Ultra/Wide SCSI Host Adapter (UDWIS/S) n/a
X2222A 595-5624 501-5727 Dual Ultra-2 SCSI/Dual FastEthernet PCI Adapter n/a
System Board
Option # Top Level
Part #
Manufacturing
Part #
Description Substitute
Part #
2761A 596-2388 501-5693 E10000 System Board 501-6336
X2720A 595-4619 501-4345 E10000 Control Board 501-4839
501-5494
X2721A 595-4945 501-4345 E10000 Control Board 501-4839
501-5494
X2722A 595-5205 501-5494 E10000 Control Board n/a
X2760A 595-4621 501-4903 E10000 System Board 501-5693
501-6336
X2761A 595-4947 501-5240 E10000 System Board 501-5693
501-6336
n/a n/a 501-6336 E10000 System Board 501-5693
n/a n/a 501-4347 E10000 System Board 501-4786
501-4903
n/a n/a 501-4786 E10000 System Board 501-4347
501-5693
501-6336
n/a n/a 501-4839 E10000 Control Board 501-4345
501-5494
n/a n/a 501-5278 E10000 System Board 501-5240
n/a n/a 501-5279 E10000 System Board 501-5240
501-5693
System Service Processor (SSP)
Option # Manufacturing
Part #
Description Substitute
Part #
X2750A 603-2997 E10000 SSP (SPARCstation 5) n/a
X2751A 600-5471 E10000 SSP (Ultra 5) n/a
X2753A 600-5931 E10000 SSP (Ultra 5+) n/a
X2754A 600-6466 E10000 SSP (Ultra 5+) n/a
X2755A 600-7415 E10000 SSP (Enterprise 250) n/a
X2757A 602-2438 E10000 SSP (Sun Fire V120) n/a




Exploded View




CODE
MANUFACTURING
PART #
DESCRIPTION
1 540-3059 Processor Cabinet
2 340-4526
340-4538
Flat Side Panel (Option 9693)
Flat Side Panel without Logo
3 540-3066 Circuit Breaker (×11 on each side)
4 350-1153
350-1184
Curved Side Panel ("Styling Panel")
Curved Side Panel without Logo
5 501-4365 Fan Tray Centerplane
6 540-3543 Left Front/Rear Door
7
-
540-3542
340-4537
Right Front/Rear Door
Front/Rear Door Foam Air Filter
8 540-3065
540-3409
540-3075
Fan Tray
Fan Tray (Option 9671)
Fan Tray Filler Panel
9 540-3060
540-3069
Rear AC/DC Power Shelf (SYS 0-7, FAN 0-1)
Front AC/DC Power Shelf (SYS 8-15, FAN 2-3)
NS
NS
370-2845
555-1897
Card Cage Air Filter
Card Cage Air Filter Kit with 8× 370-2845
NS 370-2887 Centerplane Removal Handle Set
NS 540-3063 System Board Filler Panel
NS 540-3064 Control Board Filler Panel
NS 540-3068 Remote Power Control Module Shelf
NS 530-2265 AC Power Cord, Harting Han 6HsB to NEMA L6-30P
NS 530-2266 AC Power Cord, Harting Han 6HsB to IEC309
NS 530-2567 AC Power Cord, Harting Han 6HsB to NEMA L6-30P
NS 530-2568 AC Power Cord, Harting Han 6HsB to IEC309
NS 530-2379 AC Y Power Cord, NEMA L6-30P, 20' (obsolete)
NS 530-2380 AC Y Power Cord, IEC309 (obsolete)
NS 530-2391 48Vdc Front Power Shelf to Rear Power Shelf Cable, .3M
NS 530-2392 48Vdc Cardcage to Power Shelf Cable, 610 mm
NS 530-2393 48Vdc Cardcage to Power Shelf Cable, 1270 mm
NS 530-2394 Cardcage Sense Cable, .9M
NS 530-2395 Cardcage Sense Cable, 1.3M
NS 530-2396 Centerplane and Upper Fan Power Cable
NS 530-2397 Fan Signal Ribbon Cable
NS 530-2398 Fan Sense Ribbon Cable
NS 530-2399 Lower Fan Power Cable
NS 530-2400 Control Board to Remote Power Control Cable, 3M
NS 530-2401 Control Board to Remote Power Control Cable, 1.5M
NS 530-2402 AC Sequencer to Remote Power Control Cable, .5M
NS 530-2403 AC Sequencer to Remote Power Control Cable, 6M
NS 530-2475 Internal Power Shelf Circuit Breaker Cable
NS 530-2476 Internal Power Shelf Cable, 305 mm
NS 530-2477 Internal Power Shelf Cable, 660 mm
NS 530-2503 AC Y Power Cord, NEMA L6-30P, 14.75' (obsolete)
NS 530-2802 Dual Power Option 48Vdc Cable
NS 530-2880 Dual Power Option Status Module I/O Cable
NS 530-2993 AC Y Power Cord, NEMA L6-30P, 14.75', Option 3865
NS 530-2994 AC Y Power Cord, IEC309, Option 3851
NS 540-4387 Dual Power Option Status Module
NS
-
-
565-1673
340-2348
330-1265
SBus Accessory Kit
Bracket (×5)
Handle (×5)
NS 595-5120 UniPack Mounting Tray Option X9645A